Panic Bars - Model 2000 - Touch Bar


(Images for illustrative purposes only)

Panic Bar Model 2000 – Touch Bar


General Description:

The Model 2000 – Touch Bar anti-panic bars are made of carbon steel painted in aluminum and/or polished stainless steel, with accessories in the same standard.

Recommended for fire, metal, wood, aluminum and other types of doors.

Specially developed for emergency exit doors and escape routes in high-traffic locations such as cinemas, churches, hospitals and public buildings.


Standards and Certifications


▸ Manufactured in accordance with standard NBR 11785. ▸ Tested and approved by the Falcão Bauer Institute, according to Test Report No. CCC/229.956/11 — This laboratory is accredited by INMETRO.

regulatory NBR 11785.



Construction and Materials


▸ Painted carbon steel or polished stainless steel structure. ▸ Galvanized steel accessories, resistant to clean environments or harsh industrial work. ▸ Suitable for single or double leaf doors.


Performance and Security


▸ Ensures quick and safe exit for any individual, with minimal physical effort. ▸ Eliminates the need for keys or auxiliary objects for opening. ▸ Allows immediate evacuation of the environment in emergency situations.

Options and Customizations


TEKIN panic bars can be equipped with additional accessories, depending on the project's needs:

  • Handle with key – COD 203
  • Handle without key – COD 202 (for opening from outside to inside) ▸ Possibility of changing the measurements for non-standard doors, upon request.

  • Terminology and Standards

    Escape Routes and Emergency Exits


    ▸ A continuous, protected path marked with appropriate symbols, indicating the safe route for evacuation in case of emergency. ▸ Ensures that the individual reaches a refuge area safely, preserving their physical integrity.


    Fire Doors and Fire Safety


    ▸ Every fire door has a fire resistance rating (rated in minutes) and is part of a fire protection system consisting of the door, hinges, panic device, and automatic closing system. ▸ Its purpose is to contain fire and smoke, enabling safe evacuation and reducing risks. ▸ Each country follows its own regulations and Fire Department guidelines.


    Requirements of Brazilian Legislation

    

    ▸ National legislation requires that all fire doors remain closed at all times. ▸ Overhead door closers are considered the safest and most reliable device for ensuring automatic closing in emergencies. ▸ Only closers tested in accordance with European standard EN 1154, with a closing force equal to or greater than level 3, should be used.

     

    Related Technical Standards (National and International)

    National:


    ▸ NBR 11785 – Brazilian standard that determines the requirements for the manufacture, resistance and operation of panic bars intended for emergency exits.

    ▸ NBR 6479 – Brazilian standard that certifies and determines the tests for classifying the fire resistance of the FIRE SET, consisting of: fire door, frame and hardware (hinges, anti-panic bars and air springs).

    ▸ IT 11/2011 – Technical instruction from the Fire Department (SP) that determines the sizing and requirements for emergency exits.

    ▸ NBR 11742 – Standard that determines the requirements for the manufacture, resistance and operation of fire doors intended for emergency exits. International:

     

    International:

    ▸ EN 1125 – Panic Exit Devices (European standard for panic devices with horizontal bar).

     

    Tekin has a wide range of transfer products, each designed for a specific purpose (need). Tested and quality-assured products, a quality that builds trust because they have undergone rigorous industry and other testing.


    Model

    2000 S

    2000 D

    2000 SI

    2000 OF

    Table of materials

    Simple Anti-Panic Bar - Aluminum Color - Right/Left Opening

    Double Panic Bar - Aluminum Color - Right/Left Opening

    Simple Anti-Panic Bar - Stainless Steel Color - Right/Left Opening

    Double Anti-Panic Bar - Stainless Steel Color - Right/Left Opening